10 Troubleshooting
10 - 11
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Warning
display
Warning display conditions
1st Frequency Upper Limit (A061)
1st Maximum Frequency (A004)
1st Frequency Lower Limit (A062)
1st Maximum Frequency (A004)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
1st Maximum Frequency (A004)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
1st Frequency Upper Limit (A061)
1st Frequency Lower Limit (A062)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
Starting Frequency (b082)
1st Frequency Upper Limit (A061)
Starting Frequency (b082)
1st Frequency Lower Limit (A062)
Starting Frequency (b082)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
Starting Frequency (b082)
Jogging Frequency (A038)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
=
Jump Frequency
*1
(A063/A065/A067 ± A064/A066/A068)
Multi-step Speed Reference 1 to 15
(A021 to A035)
=
Free V/f Frequency 7 (b112)
1st Frequency Upper Limit (A061)
Free V/f Frequency 7 (b112)
1st Frequency Lower Limit (A062)
Free V/f Frequency 7 (b112)
Output Frequency Setting/Monitor (F001),
1st Multi-step Speed Reference 0 (A020)
2nd Frequency Upper Limit (A261)
2nd Maximum Frequency (A204)
2nd Frequency Lower Limit (A262)
2nd Maximum Frequency (A204)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
2nd Maximum Frequency (A204)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
2nd Frequency Upper Limit (A261)
2nd Frequency Lower Limit (A262)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Starting Frequency (b082)
2nd Frequency Upper Limit (A261)
Starting Frequency (b082)
2nd Frequency Lower Limit (A262)
Starting Frequency (b082)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
=
Jump Frequency
*1
(A063/A065/A067 ± A064/A066/A068)
Free V/f Frequency 7 (b112)
2nd Frequency Upper Limit (A261)
Free V/f Frequency 7 (b112)
2nd Frequency Lower Limit (A262)
Free V/f Frequency 7 (b112)
Output Frequency Setting/Monitor (F001),
2nd Multi-step Speed Reference 0 (A220)
10
10-1 Alarm Display and Reme-
dies
10-1-4 Warning Display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC