8 Communications Functions
8 - 15
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
No.
Field name
Example
[hex]
1
Slave address
*1
01
2
Function code
06
3
Register address (MSB)
*2
00
4
Register address (LSB)
*2
01
5
Written data (MSB)
13
6
Written data (LSB)
88
7
CRC-16 (MSB)
D5
8
CRC-16 (LSB)
5C
No.
Field name
Example
[hex]
1
Slave address
*1
01
2
Function code
08
3
Test sub code (MSB)
00
4
Test sub code (LSB)
00
5
Data (MSB)
Any
6
Data (LSB)
Any
7
CRC-16 (MSB)
CRC
8
CRC-16 (LSB)
CRC
8
8-5 Explanation of Each Function Code
8-5-5 Loop-back Test [08 hex]
Example. Perform a Loop-back Test on Inverter with Slave Address 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC