8 Communications Functions
8 - 73
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function
name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1415
hex
1414 hex
Multi-function
Output 11
Selection
C021
R/W
00:
RUN
(During
RUN)
01: FA1 (Constant speed arrival signal)
02: FA2 (Set frequency exceeded signal)
03: OL (Overload warning)
04: OD (Excessive PID deviation)
05: AL (Alarm signal)
06:
FA3
(Set-frequency
only
signal)
07: OTQ (Overtorque/Undertorque signal)
09: UV (Signal during undervoltage)
10: TRQ (Torque limit)
11: RNT (RUN time over)
12:
ONT
(Power
ON
time
over)
13: THM (Electronic thermal warning)
19: BRK (Brake release)
20: BER (Brake error)
21:
ZS
(0-Hz
detection
signal)
22: DSE (Excessive speed deviation)
23: POK (Position ready)
24: FA4 (Set frequency exceeded signal 2)
25: FA5 (Set-frequency only signal 2)
26:
OL2
(Overload
warning
2)
27:
ODc (Analog O disconnection detection)
28: OIDc (Analog OI disconnection
detection)
31: FBV (PID feedback comparison)
32:
NDc (Communications disconnection detection)
33: LOG1 (Logic operation output 1)
34:
LOG2
(Logic
operation
output
2)
35: LOG3 (Logic operation output 3)
39: WAC (Capacitor life warning)
40: WAF (Cooling fan life warning)
41: FR (Starting contact signal)
42: OHF (Cooling fin overheat warning)
43: LOC (Low current signal)
44:
MO1
(General-purpose
output
1)
45:
MO2
(General-purpose
output
2)
46: MO3 (General-purpose output 3)
50: IRDY (Operation ready)
51: FWR (Forward run)
52:
RVR
(Reverse
run)
53:
MJA
(Fatal
fault
signal)
54: WCO (Window comparator O)
55: WCOI (Window comparator
OI)
58: FREF (Frequency reference source)
59: REF (RUN command source)
60: SETM (Motor 2 selection)
62: EDM (Safety device monitor signal)
63: OPO (Option)
255: no (No allocation)
P. 5-54
1416
hex
1415 hex
Multi-function
Output 12
Selection
C022
R/W
1417 to
1419
hex
Reserved
8
8-9 Modbus Communication Data Lists
8-9-4 Group A/b/C/H/P Register List

Table of Contents