Itala cameras have been tested in climatic chamber in order to prove the temperature capabilities.
Case temperature must not be exceed the range -25°C ÷ 65°C.
NOTE: The case temperature has been measured on the external part of the aluminum case, near
the mount of the camera.
CAUTION: Ambient and case temperatures can highly differ in case of poor heat
dissipation: the user must monitor Itala temperature in order to avoid damage to
the device.
Opto Engineering will not be responsible in case of overheating faults.
CAUTION: Image sensor has an operating temperature ranging from -30°C to +75°C.
Please monitor the Device Temperature feature in order not to exceed the allowed
range.
CAUTION: Be aware that image sensor quality easily degradates when its tempera-
ture exceedes the range -10°C ÷ +60°C.
3.4 Cleaning and maintenance
Even if the camera is equipped with a rugged mechanical case, some measures must be followed
in order not to damage the camera itself.
In particular, when cleaning the Itala camera, remember:
• To avoid disassembling the camera.
• To avoid liquids or inappropriate cleaning chemicals like benzene, alcohol, spray-like clean-
ers.
• To use an appropriate soft cloth or soft brush.
The protection glass or filter placed in front of the sensor can be cleaned using compressed air or
a cotton swab soaked with isopropyl alcohol.