Itala | INSTRUCTION MANUAL
SequencerSetSelector Selects the sequencer set to
which further feature settings
applies
IInteger RW
SequencerSetSave Saves the current device state to
the sequencer set selected by
the SequencerSetSelector
ICommand W
SequencerSetLoad Loads the sequencer set selected
by SequencerSetSelector in the
device
ICommand W
SequencerSetActive Contains the currently active
sequencer set
IInteger R
SequencerSetStart Sets the initial/start sequencer
set, which is the first set used
within a sequencer
IInteger RW
SequencerPathSelector Selects to which branching path
further path settings applies
IInteger RW
SequencerSetNext Specifies the next sequencer set IInteger RW
SequencerTriggerSource Specifies the internal signal or
physical input line to use as the
sequencer trigger source
IEnumeration RW
SequencerTriggerActivation Specifies the activation mode of
the sequencer trigger
IEnumeration RW
Table 39: Sequencer Control Features
6.21.1 Sequencer overview
The purpose of the Sequencer Control is to allow the user to define a series of feature sets which
can consecutively be activated during the acquisition. Each sequencer set change is triggered by an
event configured by the user.
The execution of the sequencer is completely controlled by the device.
6.21.2 Configuration of a Sequencer set
The index of the sequencer set is given by the SequencerSetSelector. Up to 16 sequencer sets can
be configured.
The features which are actually part of a sequencer set are defined in Table 40. These features
can be selected by SequencerFeatureSelector and activated by SequencerFeatureEnable. If a
feature is enabled it is for all sequencer sets.
To configure a sequencer set the camera has to be switched into configuration mode by Sequencer-
ConfigurationMode. Then the user has to select the desired sequencer set he wants to modify with
v1.12 - eng 110