EasyManua.ls Logo

opto engineering ITALA - User Set Control

opto engineering ITALA
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Itala | INSTRUCTION MANUAL
EventFrameTriggerMissed-
FrameID
Returns the unique Identifier of
the Frame (or image) that
generated the Frame Trigger
Missed Event
IInteger R
Table 29: Event Frame Trigger Missed Data features
Feature Description Interface Access
EventLine0RisingEdge Returns the unique Identifier of
the Line 0 Rising Edge type of
Event
IInteger R
EventLine0RisingEdgeTimestamp Returns the Timestamp of the
Line 0 Rising Edge Event
IInteger R
EventLine0RisingEdgeFrameID Returns the unique Identifier of
the Frame (or image) that
generated the Line 0 Rising Edge
Event
IInteger R
Table 30: Event Line 0 Rising Edge Data features
Feature Description Interface Access
EventLine1RisingEdge Returns the unique Identifier of
the Line 1 Rising Edge type of
Event
IInteger R
EventLine1RisingEdgeTimestamp Returns the Timestamp of the
Line 1 Rising Edge Event
IInteger R
EventLine1RisingEdgeFrameID Returns the unique Identifier of
the Frame (or image) that
generated the Line 1 Rising Edge
Event
IInteger R
Table 31: Event Line 1 Rising Edge Data features
6.14 User Set Control
This section describes the features for global control of the device settings. It allows loading or
saving factory or user-defined settings.
Loading the factory default User Set guarantees a state where a continuous acquisition can be
started using only the mandatory features.
v1.12 - eng 98