Itala | INSTRUCTION MANUAL
TriggerMode Controls if the selected trigger
is active
IEnumeration RW
TriggerSoftware Generates an internal trigger ICommand RW
TriggerSource Specifies the internal signal or
physical input Line to use as
the trigger source
IEnumeration RW
TriggerOverlap Specifies the type trigger
overlap permitted with the
previous frame or line. This
defines when a valid trigger will
be accepted (or latched) for a
new frame or a new line
IEnumeration RW
TriggerDelay Specifies the delay in
microseconds (us) to apply
after the trigger reception
before activating it
IFloat RW
ExposureMode Sets the operation mode of the
Exposure
IEnumeration RW
oeShortExposureEnable Enable the short exposure
mode
IBoolean RW
oeDualExposureEnable Enable the dual exposure
mode
IBoolean RW
ExposureTime Sets the Exposure time when
ExposureMode is Timed and
ExposureAuto is Off
IFloat RW
oeWaitTime1 Time delay between the first
and second exposure in Dual
Exposure mode.
IFloat RO
oeExposureTime2 Second Exposure Time in Dual
Exposure mode.
IFloat RO
oeWaitTime2 Time to wait before a new
acquisition after the second
exposure in Dual Exposure
mode.
IFloat RO
ExposureAuto Sets the automatic exposure
mode when ExposureMode is
Timed
IEnumeration RW
oeExposureAutoMin Set the lower limit for the auto
exposure algorithm
IFloat RW
oeExposureAutoMax Set the upper limit for the auto
exposure algorithm
IFloat RW