Remove the HBA SAS Cable Assembly
3.
Remove the server fan modules.
See “Remove a Fan Module” on page 63.
4.
Remove the server mid-wall.
a.
Loosen the four green captive screws that secure the mid-wall to the server
chassis, using a No. 2 Phillips screwdriver.
b.
Lift up the mid-wall slightly to disengage it, then lift it out of the server and
set it aside.
5.
Disconnect each SAS cables from the drive backplane by pressing the latch on
the cable connectors, then pull the connectors. (1).
6.
Remove the PCIe riser from PCIe slots 3 and 4.
See “Remove the PCIe Riser From PCIe Slots 3 and 4” on page 92.
120 SPARC S7-2 Server Service Manual • March 2017