EasyManuals Logo

Oracle SPARC S7-2 Service Manual

Oracle SPARC S7-2
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
Disconnect Cables From the Server
Disconnect Cables From the Server
Caution - The system supplies standby power to the circuit boards when the power cords are
connected even when the system is powered off.
1.
Label all cables connected to the server.
2.
Power down the server.
See “Power Off the Server” on page 38.
3.
Disconnect the power cords from the rear of the server.
4.
Disconnect all data cables from the rear of the server.
5.
Gain access to the internal server components.
See “Accessing Server Components” on page 40.
Related Information
“Rear Panel Components” on page 13
“Extend the Server to the Service Position” on page 41
“Reconnect Data Cables and Power Cords” on page 149
Accessing Server Components
These topics explain how to access components on the outside and the inside of the server.
Perform these tasks in this order, as needed.
“Prevent ESD Damage” on page 41
“Extend the Server to the Service Position” on page 41
“Remove the Cable Management Arm” on page 42
“Remove the Server From the Rack” on page 47
“Open the Server Fan Door” on page 48
“Remove the Top Cover” on page 49
Related Information
“Safety Information” on page 33
40 SPARC S7-2 Server Service Manual • March 2017

Table of Contents

Other manuals for Oracle SPARC S7-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle SPARC S7-2 and is the answer not in the manual?

Oracle SPARC S7-2 Specifications

General IconGeneral
BrandOracle
ModelSPARC S7-2
CategoryServer
LanguageEnglish

Related product manuals