Verify the Drive Backplane
2.
Reconnect the drive backplane power cable to the drive backplane (2).
3.
Reconnect the drive backplane auxiliary power and signal cable to the drive
backplane (4).
4.
Reconnect the SAS cables and the NVMe card cables to the drive backplane (5).
5.
Reinstall all of the storage drives into the storage drive cage.
See “Install a Drive” on page 56.
6.
Install the disk cage cover.
7.
Install all four fan modules.
See “Install a Fan Module” on page 65.
8.
Return the server to operation.
See “Returning the Server to Operation” on page 145.
Related Information
■
“Remove the Drive Backplane” on page 127
Verify the Drive Backplane
1.
At the Oracle ILOM prompt, start the fault management shell.
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
faultmgmtsp>
2.
Type fmadm faulty to check for faults.
■ If faults are reported, see “Detecting and Managing Faults” on page 21 .
■ If no faults are reported, then the drive backplane has been replaced
successfully.
Related Information
■
“Remove the Drive Backplane” on page 127
132 SPARC S7-2 Server Service Manual • March 2017