Verify a DIMM
If this command reports a fault with a UUID go to Step 6. If show faulty does not report a
fault with a UUID, you are done with the verification process.
6.
Switch to the system console and type the fmadm repair command with the UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show faulty
command. For example, type:
# fmadm repair 7c7efb20-3333-e2d7-b8ea-986b3e9dbaa9
Related Information
“DIMM Layout and Population Rules” on page 75
“Identify and Remove a Failed DIMM” on page 76
82 SPARC S7-2 Server Service Manual • March 2017