Verify a DIMM
-> start /HOST/console
...
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Note - The server might boot automatically at this point. If so, go to Step 3f. If the server
remains at the OpenBoot prompt (ok) go to the next step.
e.
If the server remains at the OpenBoot prompt, type boot.
f.
Return the virtual keyswitch to Normal mode.
-> set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
g.
Switch to the system console and type:
# fmadm faulty
If any faults are reported, refer to the diagnostics instructions described in “Identify
Faulted Components” on page 22.
4.
Switch to the Oracle ILOM command shell.
5.
Type:
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/CMP0/MCU0/CH0/D0
/SP/faultmgmt/0 | timestamp | Mar 18 16:02:56
/SP/faultmgmt/0/ | sunw-msg-id | SPSUN4V-8001-OJ
faults/0 | |
/SP/faultmgmt/0/ | uuid | 2782ad0c-91cb-c780-9663-807f0bf806df
faults/0 | |
/SP/faultmgmt/0/ | timestamp | Mar 18 16:02:56
faults/0 | |
Servicing DIMMs 81