8.2 What to Do If an Error Occurs
8-5
4. Press the [Yes] button.
The positioning error log will be cleared.
5. Press the [Close] button.
It returns to the "Status Display" dialog box.
6. Press the [Clear errors] button.
The display of the self-diagnostic error message will be cleared.
7. Correct the positioning parameters or positioning tables according to the
positioning error code confirmed in step 2.
8. Download the corrected positioning parameters or positioning table data.
Error Codes and How to Handle Them
1 to 9 Syntax error occurs.
Change to PROG. mode and clear the error.
Execute a total-check function using FPWIN GR7 to determine the
location of the syntax error and correct the program.
20 or more
Self-diagnostic error
occurs.
Refer to the list of error codes and correct the settings or programs.
Use the programming tool in PROG. mode to clear the error.
• In the case of an error code 43 or higher, the error can be cleared by
pressing the [Clear errors] button in the "Status Display" dialog box. In the
PROG. mode, the power supply can be turned off and then on again to clear
the error, but all of the contents of the operation memory except hold type
data will be cleared.
• When the positioning error (error code 44) occurs, the detailed information
on the error can be confirmed. Press the [Positioning errors] button to
check the error code.
• When an operation error (error code 45) occurs, the address at which the
error occurred is stored in special data registers DT90017 and DT90018. If
this happens, click on the “Operation errors” button in the “Status display
dialog box” and confirm the address at which the error occurred before
canceling the error.