Name Description Value Range Links
Current IP
Address
Indicates the current IP address
of the SIP Extension (reference
only).
1.0.0.0–223.255.255.255
Feature Manual
References
5.2.2 SIP (Session
Initiation Protocol)
Extension
MWI Method Selects the method of receiving
Message Waiting Indications for
SIP extensions.
Standard, Unsolicited
Note
If "Standard" is
selected, a maximum
of 64 SIP extensions
can be used.
Feature Manual
References
2.20.1 Message
Waiting
5.2.2 SIP (Session
Initiation Protocol)
Extension
Option
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Name Description Value Range Links
Extension
Number (SIP
Username)
Specifies the extension number (SIP
Username) of the port.
Max. 5 digits
(consisting of 0–9)
Feature Manual
References
5.2.2 SIP (Session
Initiation Protocol)
Extension
Password Specifies the password used for
registering a SIP Extension to the
PBX. While it is possible to enter a
password manually for each SIP
Extension, you can copy the value for
Extension Number to Password by
clicking the Copy to button. This
parameter can only be modified when
the virtual SIP extension port is set to
OUS, and the programmer must be in
On-line mode.
4–16 characters
(consisting of 0–9, a–z,
A–Z)
Feature Manual
References
5.2.2 SIP (Session
Initiation Protocol)
Extension
Connection Indicates the port status. To change
the status of the port, click the desired
cell in the column, and then select INS
or OUS for the port. This option is only
available in On-line mode.
INS: The port is in
service
OUS: The port is out of
service
Fault: The port is not
communicating with
the network.
Feature Manual
References
5.2.2 SIP (Session
Initiation Protocol)
Extension
Bearer Selects the bearer mode. When
Automatic is selected, the bearer
mode is set to Speech automatically.
Automatic, Speech,
Audio
Feature Manual
References
5.2.2 SIP (Session
Initiation Protocol)
Extension
9.16 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-SIPEXT
PC Programming Manual 237