Maintenance Console Location
9.2.1 PBX Configuration—[1-1] Configuration—Slot—System Property—Main
V-IPGW–GW Settings–Main
GW Name
Specifies the name of the destination gateway device for programming reference.
Value Range
Max. 20 characters
Maintenance Console Location
9.2.1 PBX Configuration—[1-1] Configuration—Slot—System Property—Main
GW IP Address
Specifies the IP address of the destination gateway device.
Value Range
1.0.0.0–223.255.255.255
Maintenance Console Location
9.2.1 PBX Configuration—[1-1] Configuration—Slot—System Property—Main
GW Group
Specifies the number of the gateway group to which the gateway entry belongs. A maximum of 256 gateway
groups can be created.
Value Range
1–256, None
Maintenance Console Location
9.2.1 PBX Configuration—[1-1] Configuration—Slot—System Property—Main
Connection for IP-GW
Enables the use of the Voice Activity Detection feature between the V-IPGW and KX-TDE/KX-TDA IP-GW
cards.
Value Range
Disable (TDE), Enable (TDA)
Maintenance Console Location
9.2.1 PBX Configuration—[1-1] Configuration—Slot—System Property—Main