Feature Guide References
5.2.2.3 Simple Remote Connection
UT Extension—PERIODIC Ability
Specifies whether alive monitoring is performed for connected remote extensions.
Value Range
Disable, Enable
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
UT Extension—PERIODIC Packet Sending Interval Time (s)
Specifies the polling interval for alive monitoring when PERIODIC Ability is set to Enable.
Value Range
30–3600 s
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection
Option—NAT - RTP IP Address
Specifies the RTP server’s IP address. If using a separate IP address from Common—NAT - External IP
Address, configure this setting.
Value Range
Blank, 1.0.0.1–223.255.255.254
Maintenance Console Location
9.2.2 PBX Configuration—[1-1] Configuration—Slot—System Property—Site
Feature Guide References
5.2.2.3 Simple Remote Connection