SLT Pulse Minimum Make Width
Specifies the minimum length of the make signal in a pulse dial.
Value Range
8 ´ n (n=1–5) ms
Maintenance Console Location
9.21 PBX Configuration—[1-1] Configuration—Slot—Extension—Card Property
SLT Flash Detection
Enables the PBX to detect the flash signal sent when an SLT user presses the hookswitch or the Flash/Recall
button.
Value Range
Disable: The PBX disconnects the line to prevent placing the call on hold.
Enable: The PBX places the call on consultation hold.
Maintenance Console Location
9.21 PBX Configuration—[1-1] Configuration—Slot—Extension—Card Property
Feature Guide References
2.13.3 Call Splitting
Flash Timing - Min.
Specifies the minimum length that a signal sent from an SLT must be for the PBX to recognise it as a hookswitch
flash signal.
Value Range
8 ´ n (n=3–63) ms
Maintenance Console Location
9.21 PBX Configuration—[1-1] Configuration—Slot—Extension—Card Property
Flash Timing - Range
Specifies the maximum length that a signal sent from an SLT can be for the PBX to recognise it as a hookswitch
flash signal.
Value Range
8 ´ n (n=3–191) ms
Maintenance Console Location
9.21 PBX Configuration—[1-1] Configuration—Slot—Extension—Card Property