Feature Guide References
2.18.2 Door Open
Timed Reminder—Repeat Counter
Specifies the number of times that an alarm is repeated.
Value Range
1–15
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
Feature Guide References
2.24.4 Timed Reminder
Timed Reminder—Interval Time (x10s)
Specifies the length of time between the repeated alarms.
Value Range
10 ´ n (n=1–120) s
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
Feature Guide References
2.24.4 Timed Reminder
Timed Reminder—Alarm Ringing Duration (x10s)
Specifies the length of time that an alarm rings.
Value Range
10 ´ n (n=1–30) s
Maintenance Console Location
10.3 PBX Configuration—[2-3] System—Timers & Counters
Feature Guide References
2.24.4 Timed Reminder
Unattended Conference—Recall Start Timer (x60s)
Specifies the length of time until the conference originator receives an Unattended Conference Recall tone.
446 PC Programming Manual
10.3 PBX Configuration—[2-3] System—Timers & Counters