Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Disconnect Parameters
Maximum Silence Time (0-60 s)
Specifies the length of silence detected by the system before the system disconnects the call.
Value Range
0–60 s
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Maximum Continuous Tone Time (0-60 s)
Specifies the length of time the system waits when a continuous tone is detected before it disconnects the call.
Value Range
0–60 s
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Maximum Cyclic Tone Time (0-60 s)
Specifies the length of time the system waits when a cyclic tone is detected before it disconnects the call.
Value Range
0–60 s
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Maximum Call Duration (0-60 min)
Specifies the maximum duration of calls. If the system detects no DTMF signals for the specified amount of
time, it terminates the call. Calls will not be terminated while playing or recording messages. If this setting is
set to "0", calls will not be terminated.
Value Range
0–60 min
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters