Pr0.16
*
Externalregenerativeresistorsetup
Range Unit Default
Related
control mode
0 to 3 —
A,B-frame:
3
C,D,E,F-frame:
0
P S T F
Caution
Withthisparameter,youcanselecteithertousethebuilt-inregenerativeresistorofthe
driver,ortoseparatethisbuilt-inregenerativeresistorandexternallyinstalltheregenerative
resistor(betweenPandBofConnectorXBincaseofAtoD-frame,betweenPandBof
ConnectorXCincaseofE-frame,betweenPandBofterminalblockincaseofF-frame).
A,B-framedriverisnotprovidedwithbuilt-inresister.
Setup value
Regenerative
resistor
to be used
Function
[0]
(CtoF-frame)
Built-in resistor
Regenerativeprocessingcircuitwillbeactivatedand
regenerativeresistoroverloadprotectionwillbetriggered
accordingtothebuilt-inresistor(approx.1%duty).
1
External
resistor
Thedrivertripsduetoregenerativeoverloadprotection
(Err18.0),whenregenerativeprocessingcircuitisactivatedand
itsactiveratioexceeds10%.
2
External
resistor
Regenerativeprocessingcircuitisactivated,butnoregenerative
over-loadprotectionistriggered.
[3]
(A,B-frame)
Noresistor
Bothregenerativeprocessingcircuitandregenerativeprotection
arenotactivated,andbuilt-incapacitorhandlesallregenerative
power.
Installanexternalprotectionsuchasthermalfusewhenyouusetheexternalregenerative
resistor.
Otherwise,theregenerativeresistormightbeheatedupabnormallyandresultinburnout,
regardlessofvalidationorinvalidationofregenerativeover-loadprotection.
Whenyouusethebuilt-inregenerativeresistor,nevertosetupothervaluethan0.Don't
touchtheexternalregenerativeresistor.
Externalregenerativeresistorgetsveryhot,andmightcauseburning.
Pr0.17
*
Loadfactorofexternalregenerative
resistor selection
Range Unit Default
Related
control mode
0 to 4 — 0 P S T F
Whenselectingtheexternalregenerativeresistor(Pr0.16=1,2),selectthecomputing
methodofloadfactorofregenerativeresistor.
Setup value Function
[0]
Regenerativeloadfactoris100%whendutyfactorofexternalregenerativeresistor
is 10 %.
1 to 4 Formanufacturer'suse(donotsetup)
Pr0.18
*
For manufacturer’s use
Range Unit Default
Related
control mode
— — 0
Plesesxedto0.
1. Details of parameter
[Class 0] Basic setting
Note
Related page
•Aparameterisdesignatedasfollows:
•ForparameterswhichNo.haveasuffixof“
*
”,changedcontentswillbevalidatedwhenyou
turnonthecontrolpower.
•P.2-12...“SystemCongurationandWiring”•P.3-32...“InputsandoutputsonconnectorX4”
Default:[]
Remarks