2-51
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
•
The parameter No. is displayed in the form of PrX.YY (X: Classication, YY: No.).
• For the details on the parameters, refer to P.4-4 “Details of parameter”.
Parametr No.
Class name Group page
Class No.
*
0 00 to 18 Basic setting Parameter for Basic setting P.2-52
1 00 to 78 Gain adjustment Parameter for Gain adjustment P.2-52
2 00 to 37 Damping control Parameter for Damping control P.2-55
3 00 to 29
Verocity/ Torque/
Full-closed control
Parameter for Verocity/ Torque/ Full-
closed control
P.2-57
4 00 to 57 I/F monitor setting Parameter for I/F monitor setting P.2-58
5 00 to 86 Enhancing setting Parameter for Enhancing setting P.2-60
6 00 to 98 Special setting Parameter for Special setting P.2-63
7 00 to 93 Special setting Parameter for Special setting P.2-66
8 00 to 19 For manufactuer's use Not be used. P.2-67
9 00 to 50 For manufactuer's use Not be used. P.2-68
15 00 to 35 For manufactuer's use Not be used. P.2-69
* The Parameter No. consists of 2 digits.
• In this document, following symbols represent each mode.
Symbol Control mode
Setup value
of Pr0.01
P Position control 0
S Velocity control 1
T Torque control 2
F Full-Closed control 6
P/S Position (1st)/Velocity (2nd) control
3 *
P/T Position (1st)/Torque (2nd) control
4 *
S/T Velocity (1st)/Torque (2nd) control
5 *
*
When you select the combination mode of 3, 4 or 5, you can select either 1st or 2nd
with control mode switching input (C-MODE).
When C-MODE is ON : 1st mode selection
When C-MODE is OFF : 2nd mode selection
Do not enter the command 10ms before/after the switching.