4-40
Pr4.01
*
SI2 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00818181h
(8487297)
P S T F
Pr4.02
*
SI3 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
0091910Ah
(9539850)
P S T F
Pr4.03
*
SI4 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00060606h
(394758)
P S T F
Pr4.04
*
SI5 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
0000100Ch
(4108)
P S T F
Pr4.05
*
SI6 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00030303h
(197379)
P S T F
Pr4.06
*
SI7 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00000f07h
(3847)
P S T F
Caution
Deviationcounterclear(CL)canbesetuponlywiththisparameter.Ifanyotherparameter
isusedforthispurpose,Err33.6Counterclearassignmenterrorwillbeissued.
Pr4.07
*
SI8 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00040404h
(263172)
P S T F
Pr4.08
*
SI9 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00050505h
(328965)
P S T F
Pr4.09
*
SI10 input selection
Range Unit Default
Related
control mode
0 to 00FFFFFFh —
00000E88h
(3720)
P S T F
Note
Caution
AssignfunctionstoSI2toSI10inputs.
Theseparametersarepresentedinhexadecimals.
Setup procedure is the same as described for Pr4.00.
Forinputpinassignmentwithdefaultsetting,alsorefertoP.3-39Controlinput.
Commandpulseinhibitioninput(INH)canbesetuponlywiththisparameter.Ifanyother
parameterisusedforthispurpose,Err33.7INHassignmenterrorwillbeissued.
1. Details of parameter
[Class 4] I/F monitor setting
Note
Related page
•Aparameterisdesignatedasfollows:
•ForparameterswhichNo.haveasuffixof“
*
”,
changedcontentswillbevalidatedwhen
youturnonthecontrolpower.
•P.3-32...“InputsandoutputsonconnectorX4”•P.6-2“ProtectiveFunction”