1-27
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
1 Before Using
the Products
6.
Permissible Load at Output Shaft
Motor
L
L/2
P
A
M
B
Radial load (P) direction Thrust load (A and B) direction
Unit : N (1 kgf=9.8 N)
Motor
series
Motor output
At assembly During running
Radial thrust
Thrust load
Radial thrust
Thrust load A
and
B-direction
A-direction B-direction
MSMF
50 W, 100 W 147 88 117.6 68.6 58.8
200 W, 400 W 392 147 196 245 98
750 W,
1.0 kW(
□
80)
686 294 392 392 147
1.0 kW(
□
100)
to 3.0 kW
980 588 686
490 196
4.0 kW, 5.0 kW 784 343
MQMF
100 W 147 88 117.6 68.6 58.8
200 W, 400 W 392 147 196 245 98
MDMF
1.0 kW to 2.0 kW
980 588 686
490 196
3.0 kW
784 343
4.0 kW,5.0 kW 1666 784 980
MGMF
850 W to 1.8 kW 980 588 686 686 196
2.4 kW
1666 784 980
1176
4902.9 kW
4.4 kW 1470
MHMF
50 W
147 88 117.6 68.6
49
100 W 58.8
200 W, 400 W 392 147 196 245 98
750 W,1.0 kW(
□
80) 686 294 392 392 147
1.0 kW(
□
130),
1.5kW
980 588 686 490 196
2.0 kW to 5.0 kW 1666 784 980 784 343
Note
When the load point varies, calculate the permissible radial load, P (N) from the distance
of the load point, L (mm) from the mounting ange based on the formula of the right ta-
ble, and make it smaller than the calculated result.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com