6.
Permissible Load at Output Shaft
Motor
L
L/2
P
A
M
B
Radial load (P) direction Thrust load (A and B) direction
Unit : N (1 kgf=9.8 N)
Motor
series
Motor output
At assembly During running
Radial thrust
Thrust load
Radial thrust
Thrust load A
and
B-direction
A-direction B-direction
MSMF
50 W, 100 W 147 88 117.6 68.6 58.8
200 W, 400 W 392 147 196 245 98
750 W,
1.0 kW(
80)
686 294 392 392 147
1.0 kW(
100)
to 3.0 kW
980 588 686
490 196
4.0 kW, 5.0 kW 784 343
MQMF
100 W 147 88 117.6 68.6 58.8
200 W, 400 W 392 147 196 245 98
MDMF
1.0 kW to 2.0 kW
980 588 686
490 196
3.0 kW
784 343
4.0 kW,5.0 kW 1666 784 980
MGMF
850 W to 1.8 kW 980 588 686 686 196
2.4 kW
1666 784 980
1176
4902.9 kW
4.4 kW 1470
MHMF
50 W
147 88 117.6 68.6
49
100 W 58.8
200 W, 400 W 392 147 196 245 98
750 W,1.0 kW(
80) 686 294 392 392 147
1.0 kW(
130),
1.5kW
980 588 686 490 196
2.0 kW to 5.0 kW 1666 784 980 784 343
Note
When the load point varies, calculate the permissible radial load, P (N) from the distance
of the load point, L (mm) from the mounting ange based on the formula of the right ta-
ble, and make it smaller than the calculated result.