1. When in Trouble
When in Trouble
What to Check ?
Various protective functions are equipped in the driver. When these are triggered, the
motor will stall due to error, the driver will turn the Servo-Alarm output (ALM) to off (open).
Error status and their measures
During the error status, the error code No. will be displayed on the front panel LED,
and you cannot turn Servo-ON.
You can clear the error status by Alarm clear input(A-CLR) in 120 ms or longer.
When overload protection is triggered, you can clear it by Alarm clear input (A-CLR)
in 10sec or longer after the error occurs. (
*
1 Table below) You can clear the Overload
protection time characteristics (refer to P.6-17) by turning off the control power supply
between L1C and L2C (100 V, 200 V) of the driver.
You can clear the above error by operating the front panel keys and setup support
softwear "PANATERM". Refer to P.2-111
“Alarm Clear Screen” of Preparation.
Be sure to clear the alarm during stop after removing the cause of the error and se-
curing safety.
6
1. When in Trouble
When in Trouble
Protective Function (What is Error Code ?)
Host
controller
Aren't the parameter
setups wrong ?
Motor does not run.
Check the cause by referring to P.2-102,
“Display of Factor of No Motor Running” of
Preparation, and then take necessary measure.
Is the wiring to Connector
X4 correct ?
Or aren't any wires pulled
off ?
Is the wiring to Connector X5
in case of full-closed control
correct ?
Or aren't any wires pulled off ?
Is the wiring to Connector X6
correct ?
Or aren't any wires pulled off ?
Isn't error code No. is displayed ?
Ground
Motor
External scale
Machine
Is the connecting portion
disconnected ?
(Broke wire, contact)
Is the wiring correct ?
Isn't the connector pulled off ?
Isn't the short wire pulled off ?
Doesn't the power voltage vary ?
Is the power turned on ?
Any loose connection ?
Is abnormal noise generated
from the motor ?
Isn't the holding
brake engaged ?
Isn't the connection
loose ?
Note
Related page
The figure above shows connections on velocity, position, torque and full-closed mode
driver.
• P.2-88 ... “How to Use the Front Panel” • P.3-32 “Inputs and outputs on connector X4”
• P.7-26 “Outline of Setup support software “PANATERM”