4-51
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Pr4.57
Position compare output assignment setting
Range Unit Default
Related
control mode
-2147483648 to
2147483647
Command
unit
0
P F
Sets output terminal corresponding to position compare 1 to 6 by bit.
Multiple position compare can be set to a single output terminal.
Set bits
bit Designation
bit0 3 Position com
bit4 7 Position com
bit8 11 Position com
bit12 15 Position com
bit16 19 Position com
bit20 23 Position com
bit24 27 Position com
bit28 31 Position com
Setvalue
Setup value Designation
0000 Invalidoutput
0001 AssignedtoSO1orOCMP1
0010 AssignedtoSO2orOCMP2
0011 AssignedtoSO3orOCMP3
0100 AssignedtoSO4orOCMP4
0101 AssignedtoSO5
0110 AssignedtoSO6
Others Formanufactureruse(donotset)