5-45
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
5. Manual Gain Tuning (Application)
Model type resonance oppression notch filter
How to Use
Set up the model-type damping filter using the following parameters.
Class No. Parameter name Function
6 61
1st resonance
frequency
Defines the resonance frequency of the model-type
damping lter's load.
The unit is [0.1 Hz].
6 62
1st resonance
damping ratio
Denes the resonance attenuation ratio of the model-
type damping lter's load.
The attenuation ratio can be set as the setup value
multiplied by 0.001. The value of 1000 results in an
attenuation of 1 (no peak). The smaller the setup value,
the smaller the attenuation ratio (higher resonance
peak).
6 63
1st anti-resonance
frequency
Defines the anti-resonance frequency of the model-
type damping lter's load.
The unit is [0.1 Hz].
6 64
1st anti-resonance
damping ratio
Defines the anti-resonance attenuation ratio of the
model-type damping lter's load.
The attenuation ratio can be set as the setup value
multiplied by 0.001. The value of 1000 results in an
attenuation of 1 (no peak). The smaller the setup value,
the smaller the attenuation ratio (higher resonance
peak).
6 65
1st response
frequency
Defines the response frequency of the model-type
damping lter's load.
The unit is [0.1 Hz].
6 66
2nd resonance
frequency
Defines the 2nd resonance frequency of the model-
type damping lter's load.
The unit is [0.1 Hz].
6 67
2nd resonance
damping ratio
Defines the 2nd resonance attenuation ratio of the
model-type damping lter's load.
The attenuation ratio can be set as the setup value
multiplied by 0.001. The value of 1000 results in an
attenuation of 1 (no peak). The smaller the setup value,
the smaller the attenuation ratio (higher resonance
peak).
6 68
2nd anti-resonance
frequency
Denes the 2nd anti-resonance frequency of the model-
type damping lter's load.
The unit is [0.1 Hz].
6 69
2nd anti-resonance
damping ratio
Denes the 2nd anti-resonance attenuation ratio of the
model-type damping lter's load.
The attenuation ratio can be set as the setup value
multiplied by 0.001. The value of 1000 results in an
attenuation of 1 (no peak). The smaller the setup value,
the smaller the attenuation ratio (higher resonance
peak).
6 70
2nd response
frequency
Denes the 2nd response frequency of the model-type
damping lter's load.
The unit is [0.1 Hz].