5-58
5. Manual Gain Tuning (Application)
Inertia ratio switching function
Related
Parameter
Combine the following 3 parameters to setup appropriate inertia ratio switching function.
Class No.
Title Function
6 10
Function
expansion setup
Sets bits related to inertia ratio switching function.
bit1 0: Invalid 1: Valid
bit2 0: Always valid 1: Valid
only when 1st gain is selected.
* bit 0 = LSB
Example)
To enable inertial ratio switching
Setup value = 8
0 04 Inertia ratio
Set 1st inertia ratio.
You can set up the ratio of the load inertia against the rotor (of
the motor) inertia.
6 13 2nd Inertia ratio
Set 2nd inertia ratio.
You can set up the ratio of the load inertia against the rotor (of
the motor) inertia.
How to Use
Select 1st inertia ratio or 2nd inertia ratio according to the inertia ratio select input (J-SEL).
Inertia ratio switching
input (J-SEL)
Applicable inertia ratio
OFF 1st Inertia ratio (Pr0.04)
ON 2nd Inertia ratio (Pr6.13)