2-5
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Caution
Use options correctly after reading Operating Instructions of the options to better understand
the precautions.
Take care not to apply excessive stress to each optional part.
1. Conformance to international standards
Composition of Peripheral Equipment
Ferrite coil
Symbol
*
1
Cable Name Amp. frame symbol
Option
part No.
Manufacturer's
part No.
Manufacturer Qty.
NF1
Power cable
(100 V)C
(200 V)C, D
DV0P1460 ZCAT3035-1330 TDK Corp.
0
(100 V)A, B
(200 V)A, B, E
1
NF2
Motor cable
(100 V)A, B, C
(200 V)A, B, C, D, E
1
(200 V)F 2
*1 For symbols, refer to the Block Diagram “Installation Environment” (P.2-4).
*2 The number of turns are 0.
Remarks
Caution
To connect the noise lter to the connector XB connection cable, adjust the sheath length
at the tip of the cable, as required.
Fix the ferrite coil in order to prevent excessive stress to the cables.
<Attaching ferrite coil>
Signal wire Wind cables the number of turns required to form the ferrite coil.
Power wire If sheathed (jacketed): remove the sheath (jacket) to the length so that wires (L1,
L2, L3) can be wound on the ferrite coil (including power line dedicated lter). For
effective noise reduction capability, L1, L2 and L3 should be wound together.
If not effective, increase the number of signal noise filters (including power line
dedicated lters). (See gure below.)
Motor line When installing the ferrite coil (including motor line dedicated lter) to our optional
cable, remove the sheath (jacket) to the length so that wires can be wound on
the ferrite coil (including power line dedicated lter). For effective noise reduction
capability, U, V and W should be wound together.
If not effective, increase the number of ferrite coils (including power line dedicated
lters). (See gure below.)
Encoder line Wind cables the number of turns required to form the ferrite coil.
Sheath (jacket)
Cover
FG line
Electric wire
Sheath (jacket)
*
If not effective, increase
the number of turns.
*
If not effective, increase
the number of turns.
Cover
DV0P1460
FG line
Electric wire
Sheath (jacket)
*
If not effective, increase
the number of filters.
Cover
DV0P1460
FG line
Electric wire
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com