2-7
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in Trouble
7
Supplement
Noise Filter
Option part No.
Voltage specications
for driver
Manufacturer’s
part No.
Applicable
driver (frame)
Manufacturer
DV0P4170 Single phase 100 V/200 V SUP-EK5-ER-6 A, B-frame
Okaya Electric Ind.
DV0PM20042
3-phase 200 V
3SUP-HU10-ER-6
A, B-frame
Single phase 100 V/200 V
3-phase 200 V
C-frame
DV0P4220 Single/ 3-phase 200 V 3SUP-HU30-ER-6 D-frame
DV0PM20043 3-phase 200 V 3SUP-HU50-ER-6 E-frame
DV0P3410 3-phase 200 V
3SUP-HL50-ER-6B
F-frame
Select a noise lter whose capacity is commensurate with the power source capacity (in
consideration of the load condition).
For the detailed specications of each noise lter, contact the manufacturer.
When two or more servo drivers are used with a single noise lter at the common pow-
er source, consult with the noise lter manufacturer.
Do not run the input and output wiring on the same passage: noise resistance will drop. (Figure
at lower right)
Isolate the input and output line from each other. (Figure at lower left)
1
Isolate the input and output
2
3
4
5
6
E
Noise Filter
AC input AC output
Ground
1
The effect of the noise filter is a little.
Do not place the input and output lines
in the same duct or do not tie both in a bundle.
2
3
4
5
6
E
Noise Filter
AC input
AC output
Ground
1. Conformance to international standards
Composition of Peripheral Equipments
Related page
• P.2-10 “Driver and List of Applicable Peripheral Equipments” • P.7-108 “Options”