7-64
7
5.
Motor Characteristics
(
S-T
Characteristics
)
Supplement
MQMF series (100 W )
•
Note that the motor characteristics may vary due to the existence of oil seal or brake.
Motor model Unit
MQMF011L1
□□
MQMF012L1
□□
Brake without with without with
Oil seal without/with without/with
Output rating
W 100 100
Matched drive
MADL
□
11
□□
MADL
□
05
□□
Power supply of drive
V(AC) 100 200
Rated torque
N·m 0.32 0.32
Continuous stall torque
N·m 0.32 0.32
Max.instantaneous speed
N·m 1.11 1.11
Rated curren
A
(
rms
)
1.6 1.1
Max.instantaneous current
A
(
o-p
)
7.9 5.5
Rated rotational speed
r/min 3000 3000
Max.rotational speed
r/min 6500 6500
Rotor inertia
×10
-4
k
g
·m
2
0.15 0.18 0.15 0.18
MQMF series
(
100 W
)
* These are subject to change. Contact us when you use these values for your machine design.
Without oil seal
With oil seal
●MQMF011L1□□
Input voltage to driver: AC100 V
(Dotted line represents torque at 10 % less voltage.)
●MQMF011L1□□
Input voltage to driver: AC100 V
(Dotted line represents torque at 10 % less voltage.)
●MQMF012L1□□
Input voltage to driver: AC200 V
(Dotted line represents torque at 10 % less voltage.)
●
MQMF012L1□□
Input voltage to driver: AC200 V
(Dotted line represents torque at 10 % less voltage.)
* Continuous torque vs. ambient temp.
ambient temp. [°C]
50
70
100
75
100 20 30 40
with brake
without
brake
ratio vs. rated torque
[%]
* Continuous torque vs. ambient temp.
ambient temp. [°C]
orque
[N·m]
speed [r/min]
* Continuous torque vs. ambient temp.
ambient temp. [°C]
ratio vs. rated torque
[%]
* Continuous torque vs. ambient temp.
ambient temp. [°C]
50
100
100 20 30 40
(5500)
Peak running range
Continuous running range
1.0
0 5
0
3000 6000
orque
[N·m]
speed [r/min]
(3100)
(3700)
Peak running range
Continuous running range
1.0
0.5
0
3000 6000
·have brake and no brake
have same characteristics。
·have brake and no brake
have same character stics。
speed [r/min]
50
100
100 20 30 40
speed [r/min]
ratio vs. rated torque
[%]
50
70
100
75
100 20 30 40
with brake
without
brake
ratio vs. rated torque
[%]
orque
[N·m]
(3100)
(3700)
Peak running range
Continuous running range
1.0
0.5
0
3000 6000
(0.16)
(0.16)
(0.16)
(0.85)
(0.3)
orque
[N·m]
(5500)
Peak running range
Continuous running range
1.0
0.5
0
3000 6000
(0.16)
(0.85)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com