3% Choke 
Motor 
Power  
Input 
Voltage 
Choke  Inductance  Currents 
Drive 
Frame 
Size 
(kW/Hp) (V)   
(μH) 
50Hz  1kHz  2.5kHz Sum 
B 4/5 230 CO468341U004 854 14.95 0.39 0.00 15 
C 7.5/10 230 CO468341U011 503  25.38 0.66 0.00 26 
D 18.5/25 230 CO468341U018 208  61.63 1.59 0.00 62 
E 22/30 230 CO468341U030 177  72.50 1.87 0.00 73 
F 45/60 230 CO468341U055 92  139.57 3.60 0.00 140 
B 6/10 400 CO468325U006 1750 12.69 0.33 0.00 13 
C 15/20 400 CO468325U018 817  27.19 0.70 0.00 28 
D 30/40 400 CO468325U037 416  53.47 1.38 0.00 54 
E 45/60 400 CO468325U055 282  78.85 2.04 0.00 79 
F 90/150 400 CO468325U110 137 163.13 4.21 0.00 164 
G 180/300 400 CO468325U220 68  327.17 8.45 0.00 328 
H 280/450 400 CO468325U315 48  471.28 12.17 0.00 472 
J 315/500 400 CO468325U355 42  534.72 13.81 0.00 535 
 
Lower values for THD of current can be achieved by adding extra line impedance.