Programming
Page D-46 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
B
C
D
1
2
3
4
5
6
7
E
Parameter Descriptions
V/F SHAPE
LINEAR
FREQUENCY
= BASE FREQUENCY
100%
CONSTANT
POWER RANGE
(field weakening)
OUTPUT VOLTS
f
B
f
B
QUADRATIC LAW
CONSTANT
TORQUE
RANGE
FIXED BOOST
PREF: 21.03 Default: 0.00 % Range: 0.00 to 25.00 %
This parameter allows for no-load stator resistance voltage drop compensation. This correctly fluxes the motor (under no-load
conditions) at low output frequencies, thereby increasing available motor torque. Fixed boost can be set in addition to auto
boost and acceleration boost.
BASE FREQUENCY
0
100%
V
f
BOOST = 10%