Programming
Page D-192 890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
B
C
D
1
2
3
4
5
6
7
E
113.04 REACTIVE POWER ENERGY METER REAL _.xx 0.00 kVAR ro Output
113.05 ENERGY USED ENERGY METER REAL _.x 0.0 kW hr ro Output
114.01 PRECHARGE
CLOSED
REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
TRUE rw
114.02 DC VOLTS DEMAND REGEN CNTRL REAL 0 to 1000 V 720 V rw
114.09 SYNCHRONIZING REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
114.10 SYNCHRONIZED REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
114.11 PHASE LOSS REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
114.12 CLOSE PRECHARGE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
TRUE ro Output
114.13 ENABLE DRIVE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
114.14 STATUS REGEN CNTRL ENUM 0 : INACTIVE
1 : SYNCHRONIZING
2 : SYNCHRONIZED
3 : SUPPLY FRQ HIGH
4 : SUPPLY FRQ LOW
5 : SYNCH FAILED
SUPPLY FRQ
LOW
ro Output
114.15 BRAKE MODE REGEN CNTRL BOOL 0 : FALSE
1 : TRUE
FALSE rw
115.01 INHIBIT SPD FBK TRIP BOOL 0 : FALSE
1 : TRUE
FALSE rw
115.02 THRESHOLD SPD FBK TRIP REAL 0.00 to 300.00 % 50.00 % rw
115.03 DELAY SPD FBK TRIP REAL 0.00 to 300.00 s 10.00 s rw
115.04 TRIPPED SPD FBK TRIP BOOL 0 : FALSE
1 : TRUE
FALSE ro Output
117.01 OWN ID FIREWIRE INT _ 99 ro Output
117.02 BUS MASTER ID FIREWIRE INT _ 99 ro Output
117.03 NUMBER OF NODES FIREWIRE INT _ 0 ro Output