Command Guide
-238-
Default:
Disabled
Usage Guide:
To enable Loop Protection
Example:
To enable Loop Protection
Switch# configure terminal
Switch (config)# loop-protect
4.2.119 loop-protect shutdown-time
Command:
loop-protect shutdown-time <0-604800>
loop-protect Loop protection configuration
shutdown-time Loop protection shutdown time interval
<0-604800> Shutdown time in second
Default:
180
Usage Guide:
To configure shutdown time interval of Loop Protection
Example:
To configure shutdown time interval (888) of Loop Protection
Switch# configure terminal
Switch (config)# loop-protect shutdown-time 888
4.2.120 loop-protect transmit-time
Command:
loop-protect transmit-time <0-10>
loop-protect Loop protection configuration
transmit-time Loop protection transmit time interval
<1-10> Transmit time in second