Command Guide
-245-
Switch# configure terminal
Switch (config)# mep 1 dm 5 rdtrp interval 10 last-n 10
4.2.129 mep <Instance> dm ns
Command:
mep <Instance> dm ns
mep Maintenance Entity Point
<Instance> The MEP instance number.
dm Delay Measurement
ns Nano Seconds
Default:
us
Usage Guide:
To configure Delay Measurement of MEP
Example:
To configure Delay Measurement unit (ns) of MEP 1 as below table.
Switch# configure terminal
Switch (config)# mep 1 dm ns
4.2.130 mep <Instance> dm overflow-reset
Command:
mep <Instance> dm overflow-reset
mep Maintenance Entity Point
<Instance> The MEP instance number.
dm Delay Measurement
overflow-reset Reset all Delay Measurement results on total delay counter overflow.