EasyManua.ls Logo

Planet WGSW-20160HP - Sflow Max-Datagram-Size; Sflow Timeout

Planet WGSW-20160HP
433 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Guide
-298-
4.2.204 sflow max-datagram-size
Command:
sflow max-datagram-size <datagram_size>
sflow Statistics flow
max-datagram-size Maximum datagram size
<DatagramSize : 200-1468> bytes
Default:
None
Usage Guide:
To configure the Collector Maximum datagram size of sFlow
Example:
To configure the Collector Maximum datagram size (555 bytes) of sFlow
Switch# configure terminal
Switch (config)# sflow max-datagram-size 555
4.2.205 sflow timeout
Command:
sflow timeout <timeout>
sflow Statistics flow
timeout Receiver timeout measured in seconds. The switch decrements the timeout once per second, and as long as it
is non-zero, the receiver receives samples. Once the timeout reaches 0, the receiver and all its configuration
is reset to defaults.
<timeout: 0-2147483647> Number of seconds
Default:
None
Usage Guide:
To configure the Collector timeout of sFlow
Example:
To configure the Collector timeout (555 seconds) of sFlow
Switch# configure terminal
Switch (config)# sflow timeout 555