3. Remove drain plug (C). Drain lubricant completely.
4. Clean drain plug magnetic surface. Reinstall drain
plug with a new O-ring and torque to specification.
TORQUE
Drain Plug & Fill Plug:
14 ft-lb (19 Nm)
5. Add approximately 17-18 fluid ounces (500-550ml) of
lubricant through fill plug hole. Continue to add
lubricant to bring level to bottom of fill plug hole
threads. Do not overfill.
FLUID CAPACITY
Recommended Transaxle Lubricant:
Angle Drive Fluid
(PN 2876160 - Quart)
Capacity:
20.3 oz. (600 ml)
6. Reinstall fill plug with a new O-ring and torque to
specification above.
7. Check for leaks. Dispose of used lubricant properly.