ProntoNetLC User Manual
116
This is all represented in the following diagram:
VI.6.2 Using line 2
There are two different operation modes: SIMPLE and DOUBLE mode. In SIMPLE
mode, the unit will work as usual, that means, it cannot establish two
independent communications via IP. In DOUBLE mode, the unit can establish
two independent communications via IP.
In DOUBLE mode over IP, the following restrictions will be applied:
1.- Encoder 1 and Encoder 2 can only be set in MONO.
2.- Encoder 2 (assigned to line 2) can only be set in G722.
This configuration can be set both from the menu and from the Web Page.
ProntoNetLC
192.168.0.1
ProntoNetLC
192.168.0.2