ProntoNetLC User Manual
36
< < S E T E N C O D E R 1 > >
A A C 4 L C { A A C 4 L D } A P T X
A A C S E T B I T R A T E
{ 6 4 } 1 2 8 1 9 2 2 5 6 3 8 4
A A C S E T M O D E
{ M O N O }
A A C S E T F s
{ 4 8 } 3 2 2 4
A A C S E T C R C
O N { O F F }
NOTICE: AAC LC RESTRICTIONS
If the Bit rate > 128 Kbps the combination MONO - Fs= 24 KHz is not possible.
If the Bit Rate > 192 Kbps the combination MONO - Fs= 32 KHz is not possible.
If the Bit Rate > 256 Kbps the combination MONO is not possible.
If the Bit Rate > 256 Kbps the combination STEREO – Fs = 24 KHz is not
possible.
IV.4.8 AAC LD
13
The configuration steps are:
1. Bit rate.
2. Mode: MONO.
3. Sample rate: 48, 32 or 24 KHz
14
.
4. CRC validation on/off.
5. Auxiliary data on/off.
13
Compression mode available under license.
14
16 Khz sampling rate will be only available with SIP/SAP as streaming IP protocol.
O
O
O
O