TroubleshootingPegasus3 Product Manual
Incomplete Array
A more serious, but far less common problem is an Incomplete Array. An
incomplete
array results from a
physical drive that fails or becomes missing during:
• RAID level migration
• Disk array transport
Migration
Normally, if a physical drive or the controller fails during migration, the disk array goes critical, and you
can rebuild it.
Transport
Transport is the action of moving the physical drives of a disk array:
• To different slots in the same subsystem
• From one subsystem to another
If a physical drive fails during a transport, or you do not move all of the physical drives to their new
locations, the Pegasus Utility displays an incomplete array. When the Pegasus Utility discovers an
incomplete array, it displays a dialog box asking you to:
• Click the OKbutton to accept the incomplete array.
• Click the Cancelbutton to reject the incomplete array.
Before you accept the incomplete array, be sure all of the physical drives are present and that their drive
carriers are properly installed into the subsystem. See “Replacing a Physical Drive” on page 198.
If you choose to accept the incomplete array:
1. Click OKin the incomplete array dialog box.
2. Check the operational status of the logical drives in the array.
• If the logical drives are Critical, proceed with a rebuild.
• IfthelogicaldrivesareOfine,contactTechnicalSupport.See“Contacting Technical Support” on
page 212.
3. Restore your data from a backup source.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Pegasus3 R4 and is the answer not in the manual?

Promise Technology Pegasus3 R4 Specifications

General IconGeneral
InternalNo
Chassis typeTower
Cooling typeActive
Device classSmall & Medium Business
Fan diameter92 mm
CertificationCB, UL, cUL, TUV , BSMI, SPRING, BIS FCC, CE-EMC, VCCI, BSMI, RCM KCC
Product colorBlack
LED indicatorsYes
Number of fans1 fan(s)
Airflow (imperial)70 cfm
Management platformPegasus Utility
Cable lock slot typeKensington
RAID levels0, 1, 1E, 5, 6, 10
Data transfer rate40 Gbit/s
Storage drive size3.5 \
Storage drive capacity4000 GB
Storage drive interfaceSerial ATA
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity16 TB
Maximum supported storage capacity- TB
Number of storage drives installed4
AC input voltage100-230 V
AC input frequency50 - 60 Hz
Number of power supply units1
Power supply unit (PSU) capacity250 W
Thunderbolt version3
Thunderbolt ports quantity2
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)5 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 95 %
Cables includedAC, Thunderbolt
Weight and Dimensions IconWeight and Dimensions
Depth188 mm
Width248 mm
Height195 mm
Weight6800 g

Related product manuals