Page #185 background image
172
Promise Technology
Pegasus3 R4/R6/R8
RAID Level Migration
The term “Migration” means either or both of the following:
• Change the RAID level of a logical drive.
• Expand the storage capacity of a logical drive.
On Pegasus, RAID level migration is performed on the disk array but it applies to the logical drives.
Migration does not disturb your data. You can access the data while the migration is in progress. When
migration is done, your disk array has a different RAID level and/or a larger capacity.
Migration Requirements
The following conditions affect RAID level migration:
• The disk array and logical drive must show a green check icon.
• The Target disk array may require more physical drives than the Source disk array.
• If the Target disk array requires an EVEN number of physical drives but the Source disk array has
an ODD number, ADD a physical drive as part of the migration process.
• You cannot reduce the number of physical drives in your disk array, even if the Target disk array
requires fewer physical drives than the Source disk array.
• RAID 1 (mirroring) works with two drives only. Only a single-drive RAID 0 disk array can migrate to
RAID 1. Other RAID Levels use too many drives to migrate.
• You cannot migrate a disk array when it is Critical or performing activities such as Synchronizing,
Rebuilding, and PDM.
• For RAID 6, you can add more physical drives but you cannot change the RAID level.
Source and Target RAID Levels
The tables on the following pages show the migration options for each source logical drive by its RAID
level. The available target RAID levels are shown with their requirements.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Pegasus3 R4 and is the answer not in the manual?

Promise Technology Pegasus3 R4 Specifications

General IconGeneral
InternalNo
Chassis typeTower
Cooling typeActive
Device classSmall & Medium Business
Fan diameter92 mm
CertificationCB, UL, cUL, TUV , BSMI, SPRING, BIS FCC, CE-EMC, VCCI, BSMI, RCM KCC
Product colorBlack
LED indicatorsYes
Number of fans1 fan(s)
Airflow (imperial)70 cfm
Management platformPegasus Utility
Cable lock slot typeKensington
RAID levels0, 1, 1E, 5, 6, 10
Data transfer rate40 Gbit/s
Storage drive size3.5 \
Storage drive capacity4000 GB
Storage drive interfaceSerial ATA
Installed storage drive typeHDD
Supported storage drive typesHDD & SSD
Total installed storage capacity16 TB
Maximum supported storage capacity- TB
Number of storage drives installed4
AC input voltage100-230 V
AC input frequency50 - 60 Hz
Number of power supply units1
Power supply unit (PSU) capacity250 W
Thunderbolt version3
Thunderbolt ports quantity2
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)5 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 95 %
Cables includedAC, Thunderbolt
Weight and Dimensions IconWeight and Dimensions
Depth188 mm
Width248 mm
Height195 mm
Weight6800 g

Related product manuals