Form factor 3U 19” rack mount
Drives supported • Up to 16 3.5” drives
• 6/12 Gb SAS, 6 Gb SATA HDD and SSD
• Supports any mix of SAS and SATA drives simultaneously in the same
enclosure
IO Ports
per controller
• Four 1G IO plus One 1G Management / IO
• One 12G SFF-8644 mini-SAS connector per controller for JBOD
expansion.
Memory 8GB x 1 per ctrl (up to 64GB)
Storage
Expansion
Cascade up to twelve Vess J3600 JBOD expansion units.
Vess J3600 Series supports 16 drives per device.
Operational
RAID support 0, 1, 5, 6, 10, 50, 60
RAID stripe size 64K, 128K, 256K, 512K, 1MB
Hot Spare
Drives
Global, Dedicated and Revertible option
Specications
Power Supplies CRPS 550W; Efciency 80PLUS Certied Redundant Power Supply
Voltage AC: 100-240VAC; DC: 180-320VDC Auto-Ranging
Current (Maximum)
< 8A@100-240VAC@full load; < 8A@180-320VDC@full load
Power Conversion
Efciency
>80% @ 110V (>20% load), >80% @ 240V (>20% load)
Dimensions
(Height, Width, Depth)
131mm x 446.7mm x 507mm (5.2” x 17.6” x 19.96”)
Weight
(killograms)
R3600tiD R3600xiD R3600iD R3604D
(w/o drives) 19.8 19.8 19.7 19.9
(w drives) 31.0 31.0 30.9 31.1
Vess R3600 Series models
3
Promise Technology
Introduction