Serial port on the Vess R3600i controller
Making a Serial Connection
Before you begin, be sure the RJ11-to-DB9 serial data cable is connected between the Host PC and the Vess
R3600 enclosure, and that both machines are booted and running.
Logging Into the CLI
1. At the Login prompt, type the user name and press Enter.
The default user name is
administrator
.
2. At the Password prompt, type the password and press Enter.
The default password is
password
.
The CLI screen appears.
Then do the following actions:
1. Change your terminal emulation program settings to match the following specications:
Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: none
2. Start your PC’s terminal VT100 or ANSI emulation program.
3. Press Enter once to launch the CLI.