Communications Protocol CubiScan 125 Command Set
CubiScan 125 91
20 5 Width Numeric 000.0-999.9*
25 1 Comma Alpha (,) 2Ch
26 1 Height Identifier Alpha (H) 48h
27 5 Height Numeric 000.0-999.9*
32 2 Dimension Unit Alpha in/cm
34 1 Comma Alpha (,) 2Ch
35 1 Weight Identifier Alpha (K) 4Bh
36 6 Weight Numeric 000.00-999.99*
42 1 Comma Alpha (,) 2Ch
43 1 Dim. Wgt. Identifier Alpha (D) 44h
44 6 Dim. Weight Numeric 000.00-999.99*
50 2 Wgt./Dim.Wgt Unit Alpha lb/kg
52 1 Comma Alpha (,) 2Ch
53 1 Factor Identifier Alpha (F) 46h
54 4 Factor Numeric 0000-9999
58 1 Comma Alpha (,) 2Ch
59 1 Domestic/Int'l. Unit Alpha (D/I) 44h or 49h
60 1 End of Text Control (ETX) 03h
61 1 Carriage Return Control (CR) 0Dh
62 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Measure Command Alpha (M) 4Dh
3 1 Neg. Acknowledge Alpha (N) 4Eh
4 1 CubiScan/Host Originated Alpha (C/H) 43h or 48h
51
Corner Sensor / Measure /
Zero Error
Alpha (C/M/Z) 43h or 4Dh
6 1 End of Text Control (ETX) 03h
Pos Len Description Type Range ASCII