CubiScan 125 Command Set Communications Protocol
88 CubiScan 125
Factor Toggle
This command is used to set the dimensional factor to either domes-
tic or international.
3 1 Neg. Acknowledge Alpha (N) 4Eh
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Fact. Toggle Command Alpha (F) 46h
3 1 Dom. / Int'l Alpha (D/I) 44h or 49h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Fact. Toggle Command Alpha (F) 46h
3 1 Acknowledge Alpha (A) 41h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Fact. Toggle Command Alpha (F) 46h
3 1 Neg. Acknowledge Alpha (N) 4Eh