EasyManua.ls Logo

Quantronix CubiScan 125 - Read IP Address

Quantronix CubiScan 125
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TCP/IP Communications Setup Command Set Communications Protocol
106 CubiScan 125
Read IP Address
This command is used to read the current IP address setting from the
CubiScan 125.
3 1 IP Address Command Alpha (I) 49h
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (~) 7Eh
3 1 IP Address Command Alpha (I) 49h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (~) 7Eh
3 1 IP Address Command Alpha (I) 49h
4 1 Acknowledge Alpha (A) 41h
5
7-15
or n
IP Address Alpha
(0.0.0.0) to
(255.255.255.255)
5+n 1 End of Text Control (ETX) 03h
6+n 1 Carriage Return Control (CR) 0Dh
7+n 1 Line Feed Control (LF) 0Ah

Table of Contents

Other manuals for Quantronix CubiScan 125

Related product manuals