TCP/IP Communications Setup Command Set Communications Protocol
106 CubiScan 125
Read IP Address
This command is used to read the current IP address setting from the
CubiScan 125.
3 1 IP Address Command Alpha (I) 49h
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (~) 7Eh
3 1 IP Address Command Alpha (I) 49h
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (~) 7Eh
3 1 IP Address Command Alpha (I) 49h
4 1 Acknowledge Alpha (A) 41h
5
7-15
or n
IP Address Alpha
(0.0.0.0) to
(255.255.255.255)
5+n 1 End of Text Control (ETX) 03h
6+n 1 Carriage Return Control (CR) 0Dh
7+n 1 Line Feed Control (LF) 0Ah

Table of Contents

Other manuals for Quantronix CubiScan 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantronix CubiScan 125 and is the answer not in the manual?

Quantronix CubiScan 125 Specifications

General IconGeneral
BrandQuantronix
ModelCubiScan 125
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals