CubiScan 125 Command Set Communications Protocol
90 CubiScan 125
Measure
Receipt of this command causes the CubiScan 125 to measure and
weigh the package using the ultrasound sensors. The CubiScan 125
immediately formats the data collected and transmits it to the host
computer.
4 1 End of Text Control (ETX) 03h
5 1 Carriage Return Control (CR) 0Dh
6 1 Line Feed Control (LF) 0Ah
Pos Len Description Type Range ASCII
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Measure Command Alpha (M) 4Dh
3 1 End of Text Control (ETX) 03h
4 1 Carriage Return Control (CR) 0Dh
5 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Measure Command Alpha (M) 4Dh
3 1 Acknowledge Alpha (A) 41h
4 1 CubiScan/Host Originated Alpha (C/H) 43h or 48h
5 6 City Code Alpha 000000-ZZZZZZ
11 1 Comma Alpha (,) 2Ch
12 1 Length Identifier Alpha (L) 4C
13 5 Length Numeric 000.0-999.9*
18 1 Comma Alpha (,) 2Ch
19 1 Width Identifier Alpha (W) 57h