TCP/IP Communications Setup Command Set Communications Protocol
110 CubiScan 125
Pos Len Description Type Range ASCII
Command Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
3 1 Gateway Address Command Alpha (G) 47h
4
7-15
or n
IP Address Alpha
(0.0.0.0) to
(255.255.255.255)
4+n 1 End of Text Control (ETX) 03h
5+n 1 Carriage Return Control (CR) 0Dh
6+n 1 Line Feed Control (LF) 0Ah
Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
3 1 Gateway Address Command Alpha (G) 47h
4 1 Acknowledge Alpha (A) 41h
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah
Negative Acknowledge Format
1 1 Start of Text Control (STX) 02h
2 1 Set Command Alpha (@) 40h
3 1 Gateway Address Command Alpha (G) 47h
4 1 Neg. Acknowledge Alpha (N) 4Eh
5 1 End of Text Control (ETX) 03h
6 1 Carriage Return Control (CR) 0Dh
7 1 Line Feed Control (LF) 0Ah