RADWIN2000D+UserManual Release3.6.00 11‐4
InstallingCollocatedHSSoEODUs Chapter11
11.2InstallingCollocatedHSSoEODUs
11.2.1EthernetServices Only
UseanIDU‐HforthecollocatedODUsinsteadofseparatePoEdevices.TheIDU‐Hhastwo
LANports,oneofwhichwillbeconnectedtoaswitch.
11.2.2EthernetandTDMServices
ForRADWIN2000classODUs:ToattainLayer2connectivityforuptotwosuchODUs,you
shouldconnectoneofthetwotheIDU‐C(orIDU‐E)LANportstotheIDU‐HLANports.You
mayusethesecondIDU‐C(orIDU‐E)LANporttoconnecttoaswitch.Aspointedoutea rlier,
youmayonlycollocatetwoODUsinthisway.
11.3LinkConfigurationandHSSoE
11.3.1SetupforIllustration
WewillshowhowtosetupourdemonstrationlinkasHSMandHSCinturn.(Thesecond
collocatedlinkisasimilarunit,thesetupdetailsofwhich,neednotconcernus).
11.3.2ConfiguringtheRT‐A(HBS)asanHSM
ToconfiguretheRT‐A(HBS)asEHSSMaster:
1.LogontotheRT‐A(HBS).
2.OpentheConfigure|HubSiteSynctab.