Remote Control
R&S
®
FPC
251User Manual 1178.4130.02 ─ 07
[SENSe:]FREQuency:SPAN:FULL
This command restores the full span.
Refer to the datasheet for details on the frequency range of your R&S FPC.
Example: //Restore full span
FREQ:SPAN:FULL
Usage: Event
Manual operation: See "Full Span" on page 369
See "Full Span" on page 399
[SENSe:]FREQuency:STARt
<Frequency>
This command defines the start frequency for measurements in the frequency domain
(span > 0).
Parameters:
<Frequency> <numeric value>
Refer to the datasheet for details on the frequency range of your
R&S FPC.
*RST: 0 Hz
Default unit: Hz
Example: //Define start frequency
FREQ:STAR 20MHZ
Manual operation: See "Start Frequency" on page 368
See "Start Frequency" on page 398
[SENSe:]FREQuency:STOP <Frequency>
This command defines the stop frequency for measurements in the frequency domain
(span > 0).
Parameters:
<Frequency> <numeric value>
Refer to the datasheet for details on the frequency range of your
R&S FPC.
*RST: fmax
Default unit: Hz
Example: //Define stop frequency
FREQ:STOP 500MHZ
Manual operation: See "Stop Frequency" on page 368